Add "nooutput" pragma
Add the "nooutput" pragma which causes assembly to proceed as normal for
code with the exception that no output is generated for any instructions
under this pragma. The current address is increased as usual and the symbol
table is still constructed. However, no actual output is generated for lines
operating under this pragma.
author | William Astle <lost@l-w.ca> |
---|---|
date | Thu, 01 Nov 2018 23:07:03 -0600 |
parents | b30091890d62 |
children |
line wrap: on
line source
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN""http://www.w3.org/TR/html4/loose.dtd"> <HTML ><HEAD ><TITLE >Intel Hex</TITLE ><META NAME="GENERATOR" CONTENT="Modular DocBook HTML Stylesheet Version 1.79"><LINK REL="HOME" TITLE="LW Tool Chain" HREF="index.html"><LINK REL="UP" TITLE="Output Formats" HREF="c21.html"><LINK REL="PREVIOUS" TITLE="Motorola S-Record" HREF="x36.html"><LINK REL="NEXT" TITLE="OS9 Modules" HREF="x46.html"></HEAD ><BODY CLASS="SECTION" BGCOLOR="#FFFFFF" TEXT="#000000" LINK="#0000FF" VLINK="#840084" ALINK="#0000FF" ><DIV CLASS="NAVHEADER" ><TABLE SUMMARY="Header navigation table" WIDTH="100%" BORDER="0" CELLPADDING="0" CELLSPACING="0" ><TR ><TH COLSPAN="3" ALIGN="center" >LW Tool Chain</TH ></TR ><TR ><TD WIDTH="10%" ALIGN="left" VALIGN="bottom" ><A HREF="x36.html" ACCESSKEY="P" >Prev</A ></TD ><TD WIDTH="80%" ALIGN="center" VALIGN="bottom" >Chapter 2. Output Formats</TD ><TD WIDTH="10%" ALIGN="right" VALIGN="bottom" ><A HREF="x46.html" ACCESSKEY="N" >Next</A ></TD ></TR ></TABLE ><HR ALIGN="LEFT" WIDTH="100%"></DIV ><DIV CLASS="SECTION" ><H1 CLASS="SECTION" ><A NAME="AEN41" >2.5. Intel Hex</A ></H1 ><P >This ASCII format consists of a series of CR+LF terminated "records" of ASCII text. Each record has the following structure: a start-of-record character ":", a two-digit ASCII hex byte count, a four-digit ASCII hex address, a two- digit ASCII hex record type, an optional sequence of two-digit ASCII hex data values, and a two-digit ASCII hex checksum. The LW tool chain issues only 00, and 01 Intel Hex record types. Data records are limited to maximum of 16 data bytes in length, and paragraph alignment of addresses is favored. The address sequence of the Intel hex records directly follows that of the source file; multiple ORG directives in the source code may result in out-of-sequence addresses in the Intel Hex output. </P ><P >Intel Hex format is the other standard ASCII format accepted by most memory device programming equipment, it and the Motorola S-Record format are used for similar purposes.</P ><P >LWASM can output this format since version 4.10.</P ></DIV ><DIV CLASS="NAVFOOTER" ><HR ALIGN="LEFT" WIDTH="100%"><TABLE SUMMARY="Footer navigation table" WIDTH="100%" BORDER="0" CELLPADDING="0" CELLSPACING="0" ><TR ><TD WIDTH="33%" ALIGN="left" VALIGN="top" ><A HREF="x36.html" ACCESSKEY="P" >Prev</A ></TD ><TD WIDTH="34%" ALIGN="center" VALIGN="top" ><A HREF="index.html" ACCESSKEY="H" >Home</A ></TD ><TD WIDTH="33%" ALIGN="right" VALIGN="top" ><A HREF="x46.html" ACCESSKEY="N" >Next</A ></TD ></TR ><TR ><TD WIDTH="33%" ALIGN="left" VALIGN="top" >Motorola S-Record</TD ><TD WIDTH="34%" ALIGN="center" VALIGN="top" ><A HREF="c21.html" ACCESSKEY="U" >Up</A ></TD ><TD WIDTH="33%" ALIGN="right" VALIGN="top" >OS9 Modules</TD ></TR ></TABLE ></DIV ></BODY ></HTML >